The project in context
Technology in its operating context.
The supply combines the same instrument family with two mounting-kit size ranges. Each assembly contains one measuring channel and a sensor set; the order codes match the final invoice items.
Scope of work
- 2 Prosonic Flow 91WA1 instruments with sensors
- DN200–600 mounting kit for the first assembly
- DN600–2000 mounting kit for the second assembly
- 4–20 mA HART and pulse outputs according to the specification
Execution
The supplier specification distinguishes the configurations by their mounting kits. The packing list and commercial invoice confirm two separate single-channel packages.
Clamp-on measurement and mounting configuration
The specification describes ultrasonic transit-time measurement with sensors on the outside of the pipe. The first mounting kit is intended for DN200–600 and the second for DN600–2000.
Electrical and dispatch interfaces
Both specified configurations have 5 m sensor cables, an IP67 aluminium field housing, remote configuration and 4–20 mA HART and pulse outputs. They are specified for non-hazardous areas.
The two packages are recorded in one shipping case. The instrument weights total 16.36 kg net; the packed shipment is listed at 81 kg gross.
Outcome
The records substantiate supply of two clamp-on measuring assemblies. They do not establish the actual pipe diameter, process fluid or accuracy achieved after installation.