HMI and SCADA for operation and diagnostics

We turn process signals into clear screens, states and messages that help operators understand what equipment needs.

The whole application matters.

Visualization is designed and modified around the actual process. Operators can navigate from the plant overview to the process, equipment and fault cause. We align tags, units and states and define connections to PLCs and other systems. When a plant is extended, new signals are addressed together with existing screens, configuration and documentation. The design can include alarms, trends, historical values and operator permissions.

Scope of the solution

  • Navigation and process display design
  • Tag, unit and state configuration
  • Alarms, trends and history matched to operator needs
  • HMI/SCADA links to PLCs and higher-level systems
  • Backups, change documentation and familiarization

From operating need to design.

01

Expanding a buffer or conveyor

New positions, routes and states need to appear in controls and higher-level systems. Affected displays and links to movement control are updated.

02

Remote tank measurement

Level, temperature and separate high-level indication are connected to appropriate displays. Threshold meanings and alarm responses follow the agreed functional description.

03

Keeping changes understandable

A retrofit includes configuration transfer, communications checks and work in test and production environments. Redundant installations also require consideration of switchover and recovery.

Inputs that matter.

  • Platform, versions and licence conditions
  • Signal list and functional description
  • Operator needs and message priorities
  • Data retention and required trends
  • Roles, test environment and handover arrangements
Prepare your brief →

Outputs and acceptance.

  • Displays and configuration for the agreed scope
  • Tag, message and change lists with documentation
  • Project backup and functional test record

The actual scope and acceptance criteria depend on the application and contract.

Concrete configurations and supply scopes.

These examples describe proposed solutions and enquiry requirements. Their parameters belong to the stated project stage; completed supplies are shown separately in the project portfolio.

Offered solution

Project 0532 · 2023 · Mladá Boleslav

Control and visualization for an expanded body buffer

Control layersPLC → HMI → MES
Environmentstest and production
Documentationfunctional description, I/O tests and backups

Requirement

The conveyor buffer expansion called for coordinated mechanical, PLC, HMI and manufacturing system design.

Proposed solution

The package included PLC logic changes, EcoScreen visualization updates and iTAC/DXQ integration. Server configuration and higher-level system connections addressed test and production environments and redundant servers. Software and integration formed part of a coordinated supplier scope.

Proposed scope

  • PLC and related drive modifications
  • HMI, messages and iTAC/DXQ connections
  • Server configuration and higher-level integration
  • Start-up support, training and documentation
  • PLC, HMI and configuration backups

A concrete proposal for coordinated control and IT work. Related offers BC-0446 and BC-0447 addressed other buffers.

Discuss a similar application ↗
Offered solution

Project 0787 · 2024 · Pardubice

Storage tank measurement renewal

Base / optional tanks10 + 6
Control systemTC700 → TC800
Specified temperature points0 / +80 / +150 °C

Requirement

Remote level, high-level and temperature measurement proposed with PLC renewal and SCADA changes.

Proposed solution

The base proposal covered ten tanks, with six additional tanks as a separate option. It included replacing TC700 with TC800, extending analogue inputs, connecting measurement loops and modifying visualization. The temperature instrumentation quotation included sensor and transmitter assembly calibration at three specified points with a supplier laboratory certificate.

Proposed scope

  • Field instrumentation and related installation work
  • PLC, new loops and SCADA
  • New EPLAN documentation including an editable project
  • Planned commissioning, process tests and training
  • Arranging calibration of specified temperature assemblies

The proposed retrofit connects instruments, signals, control and documentation. Calibration points apply to the selected temperature assemblies in this proposal.

Discuss a similar application ↗

Expertise for this application.

Connect the whole solution.

Questions that shape the project.

Does the whole visualization need replacement?

Where the project, licences and platform support allow, only affected parts can be extended. When a PLC changes, addressing, communications and existing functions need review.

How can alarm overload be reduced?

The design distinguishes information, warnings and faults and gives each a clear meaning and response. Priorities and thresholds are based on the process and reviewed with the operator.

A clear brief.
A practical next step.

Send your drawings, operating parameters or a short description of the change you need. We will review the technical interfaces and propose the next steps towards a quotation, clarifying any missing information with you.

Discuss your requirements ↗Prepare a technical brief →+420 731 771 147info@emkoproject.cz