PROJECTEnquire ↗
← All technologies

Technologies / From signal to function

Electrical installations & control systems

Power, drives, sensors, PLCs and operator interfaces as a connected system. With defined functions and interfaces.

The whole application matters.

A functioning process needs agreement between mechanics, electrical installation and software. Preparation includes equipment and load lists, I/O, functional descriptions and responses to abnormal states. For retrofits, we also review the accuracy of existing drawings, backup availability and options for interfacing with the current system.

Drive power and control signalsThe upper branch supplies power from the switchboard through the drive to the motor. The lower branch connects the HMI, PLC and sensors; the PLC sends commands to the drive.POWERMSwitchboardDriveMotorCONTROLHMIPLCSensors
Solid lines: power. Dashed lines: signals and communication. Actual wiring is defined for the equipment.

From operating need to design.

01

Power and environment

Sizing considers loads, protection, installation methods, external influences and operating conditions. Switchboard and cable-route scope is developed in design.

02

Control functions

Automatic and manual operation, alarms, sequences and interlocks need a clear functional description. It forms the basis for both software and acceptance tests.

03

Changing an operating system

The migration plan defines downtime, backups, interface verification and fallback arrangements. Safety assessment reflects the actual modification.

A scope you can specify.

Inputs that matter.

  • Equipment list, voltages, loads and environment
  • Diagrams, I/O list and communication interfaces
  • Functional description and required operating modes
  • Safety functions and responsibility boundaries
  • Backup, access, training and acceptance requirements
Prepare your brief →

Outputs and acceptance.

  • The agreed installation and verified functions
  • Circuit identification, documentation and backups within scope
  • Test and inspection records appropriate to the equipment

The actual scope and acceptance criteria depend on the application and contract.

From the project portfolio.

All projects ↗
Project photograph.

Project 526 · Handling & automation

Automated battery storage project

Installation location: Mladá Boleslav, Czechia · 2023–2025

Two gantry manipulators, conveyor interfaces and battery flow control for automotive production in Mladá Boleslav. The reference covers handed-over engineering and partial delivery stages.

Broader project portfolioEngineering and partial delivery stages

2 gantry manipulators with three axes of motionDetails →
Project photograph.

Project 422 · Handling & automation

Conveyor extension and material-flow control

Location: Mladá Boleslav, Czechia · 2023–2024

Mechanical transfer stations, cross transfers and new control functions for moving sequenced trolleys between production halls in Mladá Boleslav.

Broader project portfolioEngineering and delivery milestones

2 new workstations in the technical scopeDetails →

Expertise for this application.

Connect the whole solution.

Questions that shape the project.

Can the existing PLC be retained?

This depends on its condition, support availability, spare capacity, access and required functions. Assessment should precede the retrofit decision.

Will program backups be supplied at handover?

Backups, source files, licences and access rights should be agreed in the proposal, together with secure handover and change-management arrangements.

A clear brief.
A practical next step.

Send your drawings, operating parameters or a short description of the change you need. We will review the technical interfaces and propose the next steps towards a quotation, clarifying any missing information with you.

Discuss your requirements ↗Prepare a technical brief →+420 731 771 147info@emkoproject.cz